Victron VE.Bus BMS / VE.Bus BMS V2 (BMS300200200)

Victron Energy · bms

Technische Daten (aus Herstellerdokumenten)

FeldWertBedingungQuelle
automotive EN 50498 - victron_api_2026_11
auxInputCurrentRating 1 A - victron_api_2026_11
batteryCommunicationTerminals Terminals with M8 circular connectors - victron_api_2026_11
chargeDisconnectOutput Normally high (output voltage ≈ supply voltage – 1 V) Floating when the load needs to be disconnected - victron_api_2026_11
chargeDisconnectOutputSource 1 mA - victron_api_2026_11
currentDrawLow 2 mA - victron_api_2026_11
currentDrawOff 1.5 mA - victron_api_2026_11
currentDrawRegular 10 mA - victron_api_2026_11
dCInputOperatingVoltageRange [9, 70] V - victron_api_2026_11
depth 10.5 mm - victron_api_2026_11
gxPowerCurrentRating 1 A - victron_api_2026_11
height 23.8 mm - victron_api_2026_11
Immunity EN 55014-2,EN-IEC 61000-6-1, EN-IEC 61000-6-2 - victron_api_2026_11
inputOutputTerminals Screw terminals - victron_api_2026_11
loadDisconnectOutput Normally high (output voltage ≈ supply voltage – 1 V) Floating when the load needs to be disconnected - victron_api_2026_11
loadDisconnectOutputSource 1 A - victron_api_2026_11
maxHumidity 95 % - victron_api_2026_11
operatingTempRange [-20, 50] °C - victron_api_2026_11
powerSupplyCable Recommended fuse size 0.3 A - 2.5 (dependent on devices connected to Load disconnect and pre-alarm output) - victron_api_2026_11
preAlarmCurrentRating 1 A - victron_api_2026_11
preAlarmOutput Normally free floating - In case of alarm: output voltage Vbat -0.1 V - victron_api_2026_11
protectionCategory IP20 - victron_api_2026_11
remoteTerminals Usage modes to turn the system on or off: a) ON when the L and H terminal are interconnected (switch or relay contact) b) ON when the L terminal is pulled to battery minus (V<3.5 V) c) ON when the H terminal is high (2.9 V < VH < Vbat) d) OFF in all other - victron_api_2026_11
vebusTerminals 2 x RJ45 sockets to connect to all VE.Bus products - victron_api_2026_11
weight 0.12 kg - victron_api_2026_11
width 94.5 mm - victron_api_2026_11
Frage zur Victron VE.Bus BMS / VE.Bus BMS V2 (BMS300200200) stellen