Technische Daten (aus Herstellerdokumenten)
| Feld | Wert | Bedingung | Quelle |
|---|---|---|---|
| batteryConnectionTerminalType | Screw terminals 6 mm² (10 AWG) | - | victron_api_2026_11 |
| batteryVoltageAutoSelect | 12V / 24V / 48V (Auto Select) | - | victron_api_2026_11 |
| bluetooth | ja | - | victron_api_2026_11 |
| chargeAlgorithm | Multi-stage adaptive (adjustable) | - | victron_api_2026_11 |
| chargeVoltageAbsorption | 14.4V / 28.8V / 57.6V (adjustable) | - | victron_api_2026_11 |
| chargeVoltageFloat | 13.8V / 27.6V / 55.2V (adjustable) | - | victron_api_2026_11 |
| dataCommunication | Bluetooth,VE.Direct | - | victron_api_2026_11 |
| dataRetentionPeriod | 46 d | - | victron_api_2026_11 |
| dataStored | Battery voltage,Battery current,Battery temperature,Load output Current,PV voltage,PV current | - | victron_api_2026_11 |
| depth | 60 mm | - | victron_api_2026_11 |
| height | 100 mm | - | victron_api_2026_11 |
| loadConnectionTerminalType | Screw terminals 6 mm² (10 AWG) | - | victron_api_2026_11 |
| lowVoltageLoadDisconnect | 11.1V / 22.2V / 44.4V or 11.8V / 23.6V / 47.2V or Battery Life algorithm | - | victron_api_2026_11 |
| lowVoltageLoadReconnect | 13.1V / 26.2V / 52.4V or 14V / 28V / 56V or Battery Life algorithm | - | victron_api_2026_11 |
| maxContinuousLoadCurrent12 | 20 A | - | victron_api_2026_11 |
| maxContinuousLoadCurrent24 | 20 A | - | victron_api_2026_11 |
| maxContinuousLoadCurrent48 | 1 A | - | victron_api_2026_11 |
| maxEfficiency | 98 % | - | victron_api_2026_11 |
| maxHumidity | 95 % | - | victron_api_2026_11 |
| maxPVOpenCircuitVoltage | 100 V | - | victron_api_2026_11 |
| maxPVShortCircuitCurrent | 20 A | - | victron_api_2026_11 |
| max_charge_current | 20 A | aus Victron-Feld ratedChargeCurrent | victron_api_2026_11 |
| nominalPVpower12V | 290 W | - | victron_api_2026_11 |
| nominalPVpower24V | 580 W | - | victron_api_2026_11 |
| nominalPVpower48V | 1,160 W | - | victron_api_2026_11 |
| numberOfTrackers | 1 | - | victron_api_2026_11 |
| operatingTempRange | [-30, 60] °C | - | victron_api_2026_11 |
| protectionCategory | IP22 (connection area),IP43 (electronic components) | - | victron_api_2026_11 |
| protections | Automatic load disconnect,Output short-circuit,Excessive temperature,PV reverse polarity | - | victron_api_2026_11 |
| pVConnectionTerminalType | Screw terminals 6 mm² (10 AWG) | - | victron_api_2026_11 |
| ratedChargeCurrent | 20 A | - | victron_api_2026_11 |
| selfconsumptionLoadOff | 12V: 10mA / 24 V: 8mA / 48V: 7mA | - | victron_api_2026_11 |
| selfconsumptionLoadOn | 12V: 26mA / 24V: 20mA / 48V: 19mA | - | victron_api_2026_11 |
| startUpPVDCVoltage | The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1V | - | victron_api_2026_11 |
| temperatureCompensation12V | -16 mV/°C | - | victron_api_2026_11 |
| temperatureCompensation24V | -32 mV/°C | - | victron_api_2026_11 |
| temperatureCompensation48V | -64 mV/°C | - | victron_api_2026_11 |
| temperatureSensor | Optional (Smart Battery Sense) | - | victron_api_2026_11 |
| weight | 0.65 kg | - | victron_api_2026_11 |
| width | 131 mm | - | victron_api_2026_11 |
Gerätebeziehungen
Cerbo GX (Baureihe, Praxis- und Kombinationswissen)
(Victron Energy)
Typ: kommunikation · Schnittstelle: VE.Direct (Geräte mit VE.Can-Anschluss alternativ über VE.Can) · Status: freigegeben
Einschränkung: Direkt bis zu 3 VE.Direct-Geräte, weitere über VE.Direct-zu-USB-Interface; der Cerbo GX verwaltet insgesamt bis zu 15 VE.Direct-Geräte
Einschränkung: Direkt bis zu 3 VE.Direct-Geräte, weitere über VE.Direct-zu-USB-Interface; der Cerbo GX verwaltet insgesamt bis zu 15 VE.Direct-Geräte