Victron Orion-Tr DC/DC Konverter, isoliert: 12/12-9A – 9 A (ORI121210110R)

Victron Energy · dc_dc_converter

Technische Daten (aus Herstellerdokumenten)

FeldWertBedingungQuelle
continuousOutputCurrent 9 A - victron_api_2026_11
continuousOutputPower25 110 W - victron_api_2026_11
continuousOutputPower40 85 W - victron_api_2026_11
contOutputCurrentRating25 9 A - victron_api_2026_11
dcConnectionTerminalType Screw terminals 6 mm² (10 AWG) - victron_api_2026_11
dcOutputVoltageBucket 12 V - victron_api_2026_11
depth 47 mm - victron_api_2026_11
galvanicIsolation ja - victron_api_2026_11
height 100 mm - victron_api_2026_11
inputVoltageBucket 12 V - victron_api_2026_11
inputVoltageRange [8, 17] V - victron_api_2026_11
Isolation 200 VDC - victron_api_2026_11
maxEfficiency 87 - victron_api_2026_11
maxHumidity 95 % - victron_api_2026_11
maximumOutputCurrent 12.5 A - victron_api_2026_11
maximumShortcircuitCurrent 32 A - victron_api_2026_11
max_charge_current 9 A aus Victron-Feld continuousOutputCurrent victron_api_2026_11
noLoadCurrentConsumption 50 mA - victron_api_2026_11
operatingTempRange [-20, 55] °C - victron_api_2026_11
outputVoltage 12.2 V - victron_api_2026_11
outputVoltageNoise 2 mVrms - victron_api_2026_11
outputVoltageRange [10, 15] V - victron_api_2026_11
outputVoltageTolerance 200 mVrms - victron_api_2026_11
parallelable ja - victron_api_2026_11
protectionCategory IP43 (electronic components) - victron_api_2026_11
protections Short-circuit proof,Over temperature - victron_api_2026_11
remoteOnOffTerminal ja - victron_api_2026_11
remoteOnOffTerminalConnection Screw terminal two pole - victron_api_2026_11
standbyCurrentConsumption 0.2 mA - victron_api_2026_11
underVoltageRestart 7.5 V - victron_api_2026_11
underVoltageShutdown 7 V - victron_api_2026_11
weight 0.42 kg - victron_api_2026_11
width 113 mm - victron_api_2026_11
Frage zur Victron Orion-Tr DC/DC Konverter, isoliert: 12/12-9A – 9 A (ORI121210110R) stellen