Victron MultiPlus-II 2x 120V 24/3000/70 – 24 V, 3,000 VA, 2,400 W (PMP242305132)

Victron Energy · inverter_charger

Technische Daten (aus Herstellerdokumenten)

FeldWertBedingungQuelle
aCConnectionTerminalType Screw terminals 21 mm² (4 AWG) - victron_api_2026_11
aCInputFrequencyRange [45, 65] Hz - victron_api_2026_11
aCInputVoltageRangeSingle [90, 140] VAC - victron_api_2026_11
aCInputVoltageRangeSplit [180, 280] VAC - victron_api_2026_11
aCOutputFrequency 60 Hz - victron_api_2026_11
aCOutputVoltage 120 VAC - victron_api_2026_11
AuxiliaryOutput ja - victron_api_2026_11
batteryConnectionTerminalType M8 bolts (two for positive and two for negative connection) - victron_api_2026_11
batteryVoltageNominal 24 V - victron_api_2026_11
chargeAlgorithm Adaptive, 4-stage - victron_api_2026_11
chargeVoltageAbsorption 28.8 VDC - victron_api_2026_11
chargeVoltageFloat 27.6 VDC - victron_api_2026_11
chargeVoltageStorage 26.4 VDC - victron_api_2026_11
communicationPort VE.Bus - victron_api_2026_11
communicationPortGeneral ja - victron_api_2026_11
computerProgramming ja - victron_api_2026_11
continuous_output_power 2400 W aus Victron-Feld contPowerW25 (bei 25 °C) victron_api_2026_11
contPowerVA25 3,000 VA - victron_api_2026_11
contPowerW25 2,400 W - victron_api_2026_11
contPowerW40 2,200 W - victron_api_2026_11
contPowerW65 1,700 W - victron_api_2026_11
dCInputVoltageRange [19, 33] VDC Batteriespannung am DC-Eingang, nicht die PV-Spannung victron_api_2026_11
depth 148 mm - victron_api_2026_11
fanAssistCooling ja - victron_api_2026_11
height 578 mm - victron_api_2026_11
maxAcInputCurrent 50 A - victron_api_2026_11
maxAppFeedinPower 2,500 VA - victron_api_2026_11
maxEfficiency 94 % - victron_api_2026_11
maxHumidity 95 % - victron_api_2026_11
maximumBatteryChargeCurrent 70 A - victron_api_2026_11
max_charge_current 70 A aus Victron-Feld maximumBatteryChargeCurrent victron_api_2026_11
numberAcInputs 1 - victron_api_2026_11
operatingTempRange [-40, 65] °C - victron_api_2026_11
peakPowerRating 5,500 W - victron_api_2026_11
programmableRelay AC rating: 120V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC - victron_api_2026_11
protectionCategory IP22 - victron_api_2026_11
protections Output short-circuit,Overload,High battery voltage,Low battery voltage,Over temperature,AC voltage on inverter output,Excessive DC ripple - victron_api_2026_11
relayTerminal Screw terminal 3-pole - victron_api_2026_11
remoteTerminal On / Off - victron_api_2026_11
remoteTerminalType Screw terminal two pole - victron_api_2026_11
temperatureSensor Included - victron_api_2026_11
transferSwitchCurrentRating 50 A - victron_api_2026_11
vebusTerminalType Two RJ45 terminals - victron_api_2026_11
weight 22 kg - victron_api_2026_11
width 275 mm - victron_api_2026_11
zeroLoadPower 11 W - victron_api_2026_11
zeroLoadPowerAES 8 W - victron_api_2026_11
zeroLoadPowerSearch 4 W - victron_api_2026_11
Frage zur Victron MultiPlus-II 2x 120V 24/3000/70 – 24 V, 3,000 VA, 2,400 W (PMP242305132) stellen