| aCInputFrequencyRange |
[55, 65] Hz |
- |
victron_api_2026_11 |
| aCInputVoltageRangeSingle |
[90, 140] VAC |
- |
victron_api_2026_11 |
| aCInputVoltageRangeSplit |
[180, 280] VAC |
- |
victron_api_2026_11 |
| aCOutputFrequency |
60 Hz |
- |
victron_api_2026_11 |
| aCOutputVoltage |
120 VAC |
- |
victron_api_2026_11 |
| AuxiliaryOutput |
ja |
- |
victron_api_2026_11 |
| batteryVoltageNominal |
12 V |
- |
victron_api_2026_11 |
| chargeAlgorithm |
Adaptive, 4-stage |
- |
victron_api_2026_11 |
| chargeVoltageAbsorption |
14.4 VDC |
- |
victron_api_2026_11 |
| chargeVoltageFloat |
13.8 VDC |
- |
victron_api_2026_11 |
| chargeVoltageStorage |
13.2 VDC |
- |
victron_api_2026_11 |
| communicationPort |
VE.Bus |
- |
victron_api_2026_11 |
| communicationPortGeneral |
ja |
- |
victron_api_2026_11 |
| computerProgramming |
ja |
- |
victron_api_2026_11 |
| continuous_output_power |
3400 W |
aus Victron-Feld contPowerW25 (bei 25 °C) |
victron_api_2026_11 |
| contPowerW25 |
3,400 W |
- |
victron_api_2026_11 |
| contPowerW40 |
3,100 W |
- |
victron_api_2026_11 |
| contPowerW65 |
2,400 W |
- |
victron_api_2026_11 |
| dCInputVoltageRange |
[9.5, 17] VDC |
Batteriespannung am DC-Eingang, nicht die PV-Spannung |
victron_api_2026_11 |
| depth |
165 mm |
- |
victron_api_2026_11 |
| fanAssistCooling |
ja |
- |
victron_api_2026_11 |
| height |
650 mm |
- |
victron_api_2026_11 |
| maxAcInputCurrent |
50 A |
- |
victron_api_2026_11 |
| maxEfficiency |
93 % |
- |
victron_api_2026_11 |
| maxHumidity |
95 % |
- |
victron_api_2026_11 |
| maximumBatteryChargeCurrent |
160 A |
- |
victron_api_2026_11 |
| max_charge_current |
160 A |
aus Victron-Feld maximumBatteryChargeCurrent |
victron_api_2026_11 |
| numberAcInputs |
1 |
- |
victron_api_2026_11 |
| operatingTempRange |
[-40, 65] °C |
- |
victron_api_2026_11 |
| parallelOperation |
nein |
- |
victron_api_2026_11 |
| peakPowerRating |
6,000 W |
- |
victron_api_2026_11 |
| powerAssist |
ja |
- |
victron_api_2026_11 |
| powerControl |
ja |
- |
victron_api_2026_11 |
| programmableRelay |
AC rating: 120V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC |
- |
victron_api_2026_11 |
| protectionCategory |
IP22 |
- |
victron_api_2026_11 |
| protections |
Output short-circuit,Overload,High battery voltage,Low battery voltage,Over temperature,AC voltage on inverter output,Excessive DC ripple |
- |
victron_api_2026_11 |
| relayTerminal |
Screw terminal 3-pole |
- |
victron_api_2026_11 |
| remoteTerminal |
On / Off |
- |
victron_api_2026_11 |
| remoteTerminalType |
Screw terminal two pole |
- |
victron_api_2026_11 |
| temperatureSensor |
Included |
- |
victron_api_2026_11 |
| threePhaseOperation |
nein |
- |
victron_api_2026_11 |
| transferSwitchCurrentRating |
50 A |
- |
victron_api_2026_11 |
| vebusTerminalType |
Two RJ45 terminals |
- |
victron_api_2026_11 |
| weight |
25 kg |
- |
victron_api_2026_11 |
| width |
275 mm |
- |
victron_api_2026_11 |
| zeroLoadPower |
18 W |
- |
victron_api_2026_11 |
| zeroLoadPowerAES |
11 W |
- |
victron_api_2026_11 |
| zeroLoadPowerSearch |
4 W |
- |
victron_api_2026_11 |