Victron Centaur Ladegerät 12/60 – 12 V, 60 A (CCH012060000)

Victron Energy · battery_charger

Technische Daten (aus Herstellerdokumenten)

FeldWertBedingungQuelle
acConnectionTerminalType screw-clamp 4 mm² (AWG 6) - victron_api_2026_11
acInputFrequencyRange [45, 65] Hz - victron_api_2026_11
aCInputVoltageBucket 120 V - 240 V - victron_api_2026_11
aCInputVoltageRange [90, 265] V - victron_api_2026_11
batteryCapacityRange [240, 600] Ah - victron_api_2026_11
batteryConnectionTerminalType M8 bolts - victron_api_2026_11
batteryVoltageNominal 12 V - victron_api_2026_11
chargeAlgorithm IUoU, three stage charging - victron_api_2026_11
chargeCurrentNominal 60 A - victron_api_2026_11
chargeVoltageAbsorption 14.3 V - victron_api_2026_11
chargeVoltageFloat 13.5 V - victron_api_2026_11
dCInputVoltageRange [90, 400] V Batteriespannung am DC-Eingang, nicht die PV-Spannung victron_api_2026_11
depth 110 mm - victron_api_2026_11
forcedCooling ja - victron_api_2026_11
height 437 mm - victron_api_2026_11
ignitionProtected ja - victron_api_2026_11
maxHumidity 95 % - victron_api_2026_11
max_charge_current 60 A aus Victron-Feld chargeCurrentNominal victron_api_2026_11
numberOfChargeOutputs 3 - victron_api_2026_11
operatingTemperatureRange [-20, 60] °C - victron_api_2026_11
outputAmMeter ja - victron_api_2026_11
outputTemperatureDerating Up to 40°C (100°F) ambient. Output will reduce to approximately 80% of nominal at 50°C (120°F) and 60% of nominal at 60°C (140°F). - victron_api_2026_11
powerFactor 1 - victron_api_2026_11
Programable Charge voltages selectable via DIP switches - victron_api_2026_11
protectionCategory IP20 - victron_api_2026_11
protections Output short-circuit,Over temperature - victron_api_2026_11
temperatureCompensation -12 mV/°C - victron_api_2026_11
temperatureSensor Internal - victron_api_2026_11
weight 5 kg - victron_api_2026_11
width 239 mm - victron_api_2026_11
Frage zur Victron Centaur Ladegerät 12/60 – 12 V, 60 A (CCH012060000) stellen