Victron BlueSolar MPPT 150/60 – 60 A (SCC010060200)

Victron Energy · solar_charge_controller

Technische Daten (aus Herstellerdokumenten)

FeldWertBedingungQuelle
batteryConnectionTerminalType Screw terminals 35 mm² (2 AWG) - victron_api_2026_11
batteryVoltageAutoSelect 12V / 24V / 48V Auto Select (software tool needed to select 36V) - victron_api_2026_11
chargeAlgorithm Multi-stage adaptive (adjustable) - victron_api_2026_11
chargeVoltageAbsorption 14.4V / 28.8V / 57.6V (adjustable) - victron_api_2026_11
chargeVoltageFloat 13.8V / 27.6V / 55.2V (adjustable) - victron_api_2026_11
dataCommunication VE.Direct - victron_api_2026_11
dataRetentionPeriod 46 d - victron_api_2026_11
depth 95 mm - victron_api_2026_11
height 185 mm - victron_api_2026_11
lowVoltageLoadDisconnect 11.1V / 22.2V or 11.8V / 23.6V or Battery Life algorithm - victron_api_2026_11
lowVoltageLoadReconnect 13.1V / 26.2V / 52.4V or 14V / 28V / 56V or Battery Life algorithm - victron_api_2026_11
maxEfficiency 98 % - victron_api_2026_11
maxHumidity 95 % - victron_api_2026_11
maxPVOpenCircuitVoltage 150 V - victron_api_2026_11
maxPVShortCircuitCurrent 50 A - victron_api_2026_11
max_charge_current 60 A aus Victron-Feld ratedChargeCurrent victron_api_2026_11
nominalPVpower12V 860 W - victron_api_2026_11
nominalPVpower24V 1,720 W - victron_api_2026_11
nominalPVpower48V 3,440 W - victron_api_2026_11
numberOfTrackers 1 - victron_api_2026_11
operatingTempRange [-30, 60] °C - victron_api_2026_11
protectionCategory IP43 (electronic components),IP22 (connection area) - victron_api_2026_11
protections Output short-circuit,Excessive temperature,PV reverse polarity - victron_api_2026_11
pVConnectionTerminalType Screw terminals 35 mm² (2 AWG) - victron_api_2026_11
ratedChargeCurrent 60 A - victron_api_2026_11
selfConsumption 10mA - victron_api_2026_11
startUpPVDCVoltage The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1V - victron_api_2026_11
temperatureCompensation12V -16 mV/°C - victron_api_2026_11
temperatureCompensation24V -32 mV/°C - victron_api_2026_11
temperatureCompensation48V -64 mV/°C - victron_api_2026_11
temperatureSensor Internal - victron_api_2026_11
weight 3 kg - victron_api_2026_11
width 250 mm - victron_api_2026_11

Gerätebeziehungen

Cerbo GX (Baureihe, Praxis- und Kombinationswissen) (Victron Energy)
Typ: kommunikation · Schnittstelle: VE.Direct (Geräte mit VE.Can-Anschluss alternativ über VE.Can) · Status: freigegeben
Einschränkung: Direkt bis zu 3 VE.Direct-Geräte, weitere über VE.Direct-zu-USB-Interface; der Cerbo GX verwaltet insgesamt bis zu 15 VE.Direct-Geräte
Frage zur Victron BlueSolar MPPT 150/60 – 60 A (SCC010060200) stellen