Technische Daten (aus Herstellerdokumenten)
| Feld | Wert | Bedingung | Quelle |
|---|---|---|---|
| batteryConnectionTerminalType | Screw terminals 16 mm² (6 AWG) | - | victron_api_2026_11 |
| batteryVoltageAutoSelect | 12V / 24V / 48V (Auto Select) | - | victron_api_2026_11 |
| chargeAlgorithm | Multi-stage adaptive (adjustable) | - | victron_api_2026_11 |
| chargeVoltageAbsorption | 14.4V / 28.8V / 57.6V (adjustable) | - | victron_api_2026_11 |
| chargeVoltageFloat | 13.8V / 27.6V / 55.2V (adjustable) | - | victron_api_2026_11 |
| dataCommunication | VE.Direct | - | victron_api_2026_11 |
| depth | 70 mm | - | victron_api_2026_11 |
| height | 130 mm | - | victron_api_2026_11 |
| maxEfficiency | 98 % | - | victron_api_2026_11 |
| maxHumidity | 95 % | - | victron_api_2026_11 |
| maxPVOpenCircuitVoltage | 150 V | - | victron_api_2026_11 |
| maxPVShortCircuitCurrent | 40 A | - | victron_api_2026_11 |
| max_charge_current | 35 A | aus Victron-Feld ratedChargeCurrent | victron_api_2026_11 |
| nominalPVpower12V | 500 W | - | victron_api_2026_11 |
| nominalPVpower24V | 1,000 W | - | victron_api_2026_11 |
| nominalPVpower36V | 1,500 W | - | victron_api_2026_11 |
| nominalPVpower48V | 2,000 W | - | victron_api_2026_11 |
| numberOfTrackers | 1 | - | victron_api_2026_11 |
| operatingTempRange | [-30, 60] °C | - | victron_api_2026_11 |
| protectionCategory | IP22 (connection area),IP43 (electronic components) | - | victron_api_2026_11 |
| protections | PV reverse polarity,Output short-circuit,Excessive temperature | - | victron_api_2026_11 |
| pVConnectionTerminalType | Screw terminals 16 mm² (6 AWG) | - | victron_api_2026_11 |
| ratedChargeCurrent | 35 A | - | victron_api_2026_11 |
| selfConsumption | 12V: 20mA, 24V: 15mA, 48V: 10mA | - | victron_api_2026_11 |
| startUpPVDCVoltage | The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1V | - | victron_api_2026_11 |
| temperatureCompensation12V | -16 mV/°C | - | victron_api_2026_11 |
| temperatureCompensation24V | -32 mV/°C | - | victron_api_2026_11 |
| temperatureCompensation48V | -64 mV/°C | - | victron_api_2026_11 |
| temperatureSensor | Internal | - | victron_api_2026_11 |
| weight | 1.25 kg | - | victron_api_2026_11 |
| width | 186 mm | - | victron_api_2026_11 |
Gerätebeziehungen
Cerbo GX (Baureihe, Praxis- und Kombinationswissen)
(Victron Energy)
Typ: kommunikation · Schnittstelle: VE.Direct (Geräte mit VE.Can-Anschluss alternativ über VE.Can) · Status: freigegeben
Einschränkung: Direkt bis zu 3 VE.Direct-Geräte, weitere über VE.Direct-zu-USB-Interface; der Cerbo GX verwaltet insgesamt bis zu 15 VE.Direct-Geräte
Einschränkung: Direkt bis zu 3 VE.Direct-Geräte, weitere über VE.Direct-zu-USB-Interface; der Cerbo GX verwaltet insgesamt bis zu 15 VE.Direct-Geräte