Victron Blue Smart IP22 Charger 24/12 – 24 V, 12 A (BPC241242012)

Victron Energy · battery_charger

Technische Daten (aus Herstellerdokumenten)

FeldWertBedingungQuelle
acConnectionTerminalType Cable of 1.5 meter with AS/NZS 3112 plug (AU/NZ) - victron_api_2026_11
acInputFrequencyRange [45, 65] Hz - victron_api_2026_11
aCInputVoltageBucket 230 V - victron_api_2026_11
batteryConnectionTerminalType Screw terminals 16 mm² (6 AWG) - victron_api_2026_11
batteryVoltageNominal 24 V - victron_api_2026_11
bluetooth ja - victron_api_2026_11
canBeUsedAsPowerSupply ja - victron_api_2026_11
chargeAlgorithm Adaptive, 6-stage - victron_api_2026_11
chargeCurrentLow 6 A - victron_api_2026_11
chargeCurrentNominal 12 A - victron_api_2026_11
chargeVoltageAbsorption Normal: 28.8V High: 29.4V Lithium: 28.4V - victron_api_2026_11
chargeVoltageFloat Normal: 27.6V High: 27.6V Li-ion: 27.0V - victron_api_2026_11
chargeVoltageStorage Normal: 26.4V High: 26.4V Li-ion: 27.0V - victron_api_2026_11
communicationPorts Bluetooth - victron_api_2026_11
depth 65 mm - victron_api_2026_11
efficiency 94 % - victron_api_2026_11
forcedCooling ja - victron_api_2026_11
height 235 mm - victron_api_2026_11
lithiumCompatible ja - victron_api_2026_11
maxHumidity 98 % - victron_api_2026_11
max_charge_current 12 A aus Victron-Feld chargeCurrentNominal victron_api_2026_11
noLoadPowerConsumption 0.5 W - victron_api_2026_11
numberOfChargeOutputs 1 - victron_api_2026_11
operatingTemperatureRange [-20, 50] °C - victron_api_2026_11
Programable ja - victron_api_2026_11
protectionCategory IP22 - victron_api_2026_11
protections Battery reverse polarity (fuse),Output short-circuit,Over temperature - victron_api_2026_11
temperatureCompensation -32 mV/°C - victron_api_2026_11
temperatureSensor Optional (Smart Battery Sense) - victron_api_2026_11
weight 1.3 kg - victron_api_2026_11
width 108 mm - victron_api_2026_11
Frage zur Victron Blue Smart IP22 Charger 24/12 – 24 V, 12 A (BPC241242012) stellen