FeldWertBedingungQuelle
continuous_output_power 2000 W laut Mastervolt Powerbook (Katalog 2023) kat_mastervolt_2026_11
kt_ac_connection North American socket - kat_mastervolt_2026_11
kt_compliance CE, E-mark, RCM - kat_mastervolt_2026_11
kt_continuous_power_at_25_c_77_f_cos_phi 2000 W - kat_mastervolt_2026_11
kt_continuous_power_at_40_c_104_f_cos_ph 2000 W - kat_mastervolt_2026_11
kt_dimensions_hxwxd 248 x 443 x 83 mm - kat_mastervolt_2026_11
kt_display_read_out LED indication: battery voltage, load level, status - kat_mastervolt_2026_11
kt_harmonic_distortion_typical <5% - kat_mastervolt_2026_11
kt_input_current_nominal_load 100 A - kat_mastervolt_2026_11
kt_masterbus_compatible yes, using a MasterBus AC Master Interface - kat_mastervolt_2026_11
kt_minimal_cable_size 35 mm2 - kat_mastervolt_2026_11
kt_minimal_dc_fuse_slow_blow 160 A - kat_mastervolt_2026_11
kt_nominal_battery_voltage 24 V - kat_mastervolt_2026_11
kt_no_load_power_consumption_energy_savi < 0.05 A - kat_mastervolt_2026_11
kt_output_voltage 100/110/115/120 V - kat_mastervolt_2026_11
kt_output_waveform true sine - kat_mastervolt_2026_11
kt_peak_load < 2300 W (1 min) - kat_mastervolt_2026_11
kt_protections over-temperature, overload, short circuit, high/low voltage, reverse polarity (fuse) - kat_mastervolt_2026_11
kt_technology high frequency, input & output fully isolated - kat_mastervolt_2026_11
kt_temperature_range_ambient_temp -20 °C to 60 °C, derating power > 40 °C / -4 °F to 140 °F, derating power > 104 °F - kat_mastervolt_2026_11
kt_transfer_system n.a. - kat_mastervolt_2026_11
kt_weight 5.2 kg / 11.5 lb - kat_mastervolt_2026_11
kt_with_nz_au_plug 28522000 - kat_mastervolt_2026_11
kt_with_uk_plug 28522000 - kat_mastervolt_2026_11